Super Sep CONTEC CMS5100 easy carrying vital signs NIBP SPO2 Patient Monitor

FOB Reference Price:Get Latest Price
$120.00 - $200.00 / Units | 1 Unit/Units (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Type:
First-Aid Devices, First-Aid Devices
Brand Name:
CONTEC
Model Number:
CMS5100
Place of Origin:
Hebei, China
Instrument classification:
Class II
Product name:
patient monitor
Function:
NIBP SPO2
Warranty:
18-month for main unit and 6-month for accessories
Supply Ability
Supply Ability:
5000 Unit/Units per Month South Africa Unavailable
Packaging & Delivery
Packaging Details
Carton
Port
Beijing/Tianjin/Shenzhen/Shanghai
 
Super September

Now participating in Super Sep. Click to get more info of this promotion...

 

 

Product Description

 CONTEC CMS5100 Medical Portable Vital Signs   NIBP SPO2  Patient Monitor

CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.

 


Features
  Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
  Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
  Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
  Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
  With user-friendly interface.

  Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.
  Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
  Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.
   Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.


Performance
1.  NIBP monitoring
   Measurement method: Oscillometry
  Measurement mode: manual/auto/continuous.
   Auto measurement interval: adjustable from 1 to 90 minutes.
   Resolution: 1mmHg.
  Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
   Self-check function.
  Overpressure protection: double protection for software and hardware.
1)  Range
Adult:
 Systolic pressure: 40mmHg~270mmHg
 Mean pressure: 20mmHg~235mmHg
 Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
 Systolic pressure: 40mmHg~200mmHg
 Mean pressure: 20mmHg~165mmHg
 Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
 Systolic pressure: 40mmHg~135mmHg
 Mean pressure: 20mmHg~110mmHg
 Diastolic Pressure: 10mmHg~100mmHg
2)  Upper and lower limit of alarm
Adult:
 Systolic pressure: 40mmHg~270mmHg
 Mean pressure: 20mmHg~235mmHg
 Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
 Systolic pressure: 40mmHg~200mmHg
 Mean pressure: 20mmHg~165mmHg
 Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
 Systolic pressure: 40mmHg~135mmHg
 Mean pressure: 20mmHg~110mmHg
 Diastolic Pressure: 10mmHg~100mmHg


2.  SpO2 monitoring 
  Continuous real-time measuring.
 Adopt digital SpO2 technology, which has strong anti-interference capability.
  Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
  Standard finger-clip probe for adult , binding probe for neonatal is optional.
1)  SpO2 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2)  Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
3)  Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
4)  Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.


Accessories
   A power cord
   A power adapter
  A SpO2 probe
  An adult NIBP cuff
   An extending tube for blood pressure


Physical characteristic
Dimension for prodult: 190(L)×162(W)×240(H)mm
Weight: 1.6kg
Dimension for packaging: 402(L)×228(W)×320(H)mm

Patient Monitor

Multi-parameter  Patient Monitor series:  $150-600

 

ModelParametersParameters(detail)

Screen size
(inch)

Touch
screen

Central 

Monitoring 

WIFI/
Cellular
Printer
PM502NIBP/SPO2 2.4 N NN N
CMS50002NIBP/SPO2 2.4 N NN N
CMS5000C2NIBP/SPO2 2.4 N NN Y
CMS51003NIBP/SPO2/TEMP 2.8 N NN N
CMS65006NIBP/SPO2/TEMP/ECG/RESP/PR 7 Y YY Y
CMS60006NIBP/SPO2/TEMP/ECG/RESP/PR 8 N YY Y
CMS70006NIBP/SPO2/TEMP/ECG/RESP/PR 12.1 N YY Y
CMS7000 PLUS6NIBP/SPO2/TEMP/ECG/RESP/PR 12.1 Y YY Y
CMS80006NIBP/SPO2/TEMP/ECG/RESP/PR 12.1 N YY Y
CMS90006NIBP/SPO2/TEMP/ECG/RESP/PR 12.1 N YY Y
CMS68006NIBP/SPO2/TEMP/ECG/RESP/PR 8 N YY Y
CMS92006NIBP/SPO2/TEMP/ECG/RESP/PR15 N YY Y
CMS9200 PLUS6NIBP/SPO2/TEMP/ECG/RESP/PR 15 Y YY Y
HMS65009NIBP/SPO2/TEMP/ECG/RESP/PR 7 Y NY N
HMS75009NIBP/SPO2/TEMP/ECG/RESP/PR 10.1 Y NY N

For model CMS6000/6500/6800/7000/7000 PLUS/8000/9000/9200/9200 PLUS, optional functions are:

IBP, ETCO2, 12 LEAD ECG, BUILT-IN PRINTER, VGA OUTPUT, CO, MOVING BRACKET,HANGING BRACKET.